CSA G40.21 Gr 350WT plates API Std 650 aboveground petroleum storage tanks

Pressure Setting of Safety DevicesExcept as provided in API 620 tank 9.5 for certain liquid relief valves, the pressure setting of a pressure-relieving device shall in no case exceed the maximum pressure that can exist at the level where the device is located when the pressure at the top of the tank equals the nominal pressure rating for the tank (see API 620 tank 5.3.1) and the liquid contained in the tank API Std 650 aboveground petroleum storage tanks is at the maximum design level.Vacuum-relieving devices shall be set to open at such a pressure or partial vacuum that the partial vacuum in the tank cannot exceed that for which the tank is designed when the inflow of air (or other gas or vapor) through the device is at its maximum specified rate.

The characteristics of the API Std 650 aboveground petroleum storage tanks internal floating roof structure of API 650 petroleum storage tanks: the inner floating roof or inner floating plate refers to the floating roof that floats on the liquid surface of the oil tank with the oil and liquid up and down. The API Std 650 aboveground petroleum storage tanks inner floating roof is used to cover the liquid. The surface is currently recognized as the most ideal and most economical and practical way to reduce oil evaporation loss.

our company supplied 2300 ton API 5L GrB ERW pipe to Petroleum company in 2016. It takes 35 days for our company to finish all the production according to API 5L standard. The products are used to drilling , gas transmission works. And we supply the API5L PSL1 GR B original Mill Test Certificate, API5L PSL1 GR B pipes picture, the dimension test, the API Std 650 aboveground petroleum storage tanks material, heat number, supplier name and size will be shown on the surface of steel pipe.

}

Prefabrication requirements for API Std 650 aboveground petroleum storage tanks, large vertical storage tanks:
1. The machined surface of the edge of the steel plate should be smooth, and there should be no defects such as slag inclusion, delamination, cracks, etc., and the surface hardened layer produced by the flame cutting groove should be removed.
2. Dimension deviation after steel plate processing: the deviation of plate width is less than 1.5 mm, the deviation of plate length is less than 2 mm, and the difference between diagonals is less than 3 mm.

The company specializes in heavy plate cutting, carbon steel pplate processing, carbon plate welding processing and sales of wide and thick steel API Std 650 aboveground petroleum storage tanks plates. It has high-quality CNC steel plate cutting and processing equipment, a professional technical personnel team, and supporting logistics distribution and after-sales service system. BBN company provides customers with solutions at low prices, high quality, and fast response service.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!