CSA G40.21 Gr 350W plates API Std 650 aboveground welded storage tanks

Standard Hydrostatic and Pneumatic TestsAfter erection is completed and stress relieving, radiographic examinations, or other similar operations, as may be required, are performed, each tank shall satisfactorily pass a series of hydrostatic and pneumatic tests as prescribed in 7.18.2 through 7.18.6. Whenever a solution film is specified in this section to be applied to welding, linseed oil or another equivalent material for disclosing air leakage may be substituted. In freezing weather, linseed oil or a similarly suitable material shall be used.The attachment welding around all openings and their reinforcements in the walls of the API 620 tank shall be examined by the magnetic-particle method both inside and outside the tank API Std 650 aboveground welded storage tanks. When the underside of a tank bottom rests directly on the tank grade (and is not accessible after erection), such examination of welding on the underside of the bottom and subsequent air testing may be omitted.Before the start of erection, inspect each API 650 tank foundation to ensure that it is level and acceptable to receive Work. Remove temporary erection attachments welded to the interior or exterior of the API Std 650 aboveground welded storage tanks shell or to the bottom by arc gouging, and grind weld area smooth.The Philiphine customer is our old customer, and they are engaged in offshore oilfield resources drilling projects. Thus they have regular steel demands. They ordered 1008 tons API 5L grade B ERW pipes and Q345B seamless pipes from us in April 2018. And told us that is a regular demand almost every two month. Since our first success cooperation, we have cooperated with each other regularly. And they also bring us new opportunities and signification in Philippians market.High temperature heat transfer oil fin tube heating device for large API Std 650 aboveground welded storage tanks has the advantage of reducing the leakage of heating coils. The heating medium of the large storage tank heating device is high-temperature heat-conducting oil. The boiling point of the heat-conducting oil is high, usually higher than 200°C. At high temperatures, the pressure on the heat-conducting oil circulation pipeline is very small, which greatly reduces the occurrence of heating coil leakage accidents. At the same time, the temperature difference between the inside and outside of the tube is guaranteed.Due to other non-steel quality reasons caused by the customer dissatisfaction, to timely explain to the customer, and help them solve the problem, for the customer really because of their own reasons, to give patient reply.The process of objection handling is the process of our technical service.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!