ASTM A181 forgings API standard 650 larger diameter tanks
Oil tank accessories are an important component of metal oil tanks. Common accessories of API standard 650 larger diameter tanks include manholes, light holes, oil measuring holes, breathing valves, safety valves, and fire extinguishers. The functions of these accessories are different. Some are to ensure the storage quality of various oil products, some are to ensure the normal operation of oil products receiving and dispatching, and some are to ensure the safety management of API standard 650 larger diameter tanks, etc.
API 650 internal floating roof oil tank executive standard: domestic design standard: GB50341-2003 "Vertical cylindrical steel welded oil tank design code"; domestic construction standard: GB50128-2005 "vertical cylindrical steel welded oil tank" Construction and Acceptance Specification; API standard 650 larger diameter tanks Foreign design standard: API650-2007 "Standard for Welded Steel Petroleum storage tanks.
The company has huge steel API standard 650 larger diameter tanks products stock all the year round to meet the urgent needs of customers. For stock products, we can arrange delivery within 3 days. The transportation department and shipping department shall coordinate and follow up to update the progress to customers regularly, i.e. where the goods have arrived, so as to let customers not worry and rest assured. Think about what the customers think and what the customers are anxious about, solve problems for customers efficiently and effectively, is the direction of our unremitting efforts.
Inspection of Welded Storage Tanks Surfaces Exposed during FabricationThe edges of API standard 650 larger diameter tanks plates, openings and fittings exposed during fabrication shall be inspected carefully to make sure that any defects have been uncovered, as well as to determine that the work has been performed properly.Minor defects found may be repaired only after the inspector approves the method and extent of repairs. Materials that have more than minor defects that cannot be satisfactorily repaired shall be rejected.Spot radiographic or ultrasonic examination shall be not less than 6 in. extending along the weld. Spot radiography shall comply with the standards given in 7.15.1.3. Where spot radiographic or ultrasonic examination is applied at joint intersections, the surface shall be prepared and examined for a distance of 3 in. on each side of the intersection, making the minimum length of examination 6 in. on the horizontal weld and 3 in. on the vertical weld.