ASTM A105 forgings API Std 650 aboveground petroleum storage tanks
Pressure Setting of Safety DevicesExcept as provided in API 620 tank 9.5 for certain liquid relief valves, the pressure setting of a pressure-relieving device shall in no case exceed the maximum pressure that can exist at the level where the device is located when the pressure at the top of the tank equals the nominal pressure rating for the tank (see API 620 tank 5.3.1) and the liquid contained in the tank API Std 650 aboveground petroleum storage tanks is at the maximum design level.Vacuum-relieving devices shall be set to open at such a pressure or partial vacuum that the partial vacuum in the tank cannot exceed that for which the tank is designed when the inflow of air (or other gas or vapor) through the device is at its maximum specified rate.Normal pressure API 650 storage tank: When the gas side pressure of API 650 storage tank is the same as atmospheric pressure or less than 13 atmospheres (gauge), API Std 650 aboveground petroleum storage tanks is called atmospheric storage tank. API 650 petroleum storage tanks low pressure storage tank: when the pressure is greater than 13 atmospheres (gauge) and less than 0.1MPa, it is called low pressure storage tank.In 30th,Dec,2018--2th,Jan,2019, One Malaysian customer come to visit our factory to inspect their goods about CCS-AH36 steel plate. This customer is a famous shipyard in Malaysia. Their company has the business scope of tourism, API Std 650 aboveground petroleum storage tanks shipbuilding, transportation and so on. As a terminal manufacturer, they have strict requirements on quality . After visiting our factory, the customer are very satisfied with the quality of this batch of products.The cone slope of the completed API Std 650 aboveground petroleum storage tanks foundation is 15/1000 for the general foundation and less than 35/1000 for the soft foundation. After the foundation settlement of the storage tank is basically stable, the surface slope must be greater than eight thousandths. The edge of the tank bottom should be more than 0.3 meters higher than the surrounding ground. Above the ground, the tank bottom leakage detection tube should be drawn from the foundation sand cushion and cross the foundation ring wall or the slope protection surface. The circumferential distance should be less than 20 meters, and each API Std 650 aboveground petroleum storage tanks should have at least 4 detection tubes.Relying on the background of high-quality steel resources and its own strong steel machining capabilities, BBN comany can not only supply various steel material products, such as steel coils, steel plates, API Std 650 aboveground petroleum storage tanks sheet, steel pipes, and shaped steels, but also provide a variety of steel deep processing services like cutting, welding and grinding. Through continuous technological innovation and after-sales service optimization, the company has its own world on the domestic and international steel industry stage!
Latest NewsMore+