ASTM A1011M sheets API Std 650 ground supported liquid storage tanks

API standard 650 is typically used for carbon, stainless steel and aluminium API Std 650 ground supported liquid storage tanks tanks located in terminals, refineries, pipelines and other process facilities. Both have different pressure and temperature parameters as well. Your choice of model will depend on you and/or your client s particular needs.

If customers have any difficult problems during use of the steel materials, they can contact the company's after-sales service department to feedback the existing problems. The after-sales department will reply as soon as possible to ensure that each customer has a good after-sales experience. Under special circumstances, the after-sales service department will start the problem-solving process, and the engineers in charge of the area will quickly follow up to solve the problem.

API 620 Tank Standard Post-heat Treatment (Stress Relief)
The post-heat treatment now performed on pressure vessels is of established value, although the mechanism by which the improvement is realized may be open to debate. Post-heat treatment of API Std 650 ground supported liquid storage tanks tank sections when the plate thickness exceeds 11/4 in. is required as stated in 5.25. In special cases, the possibilities of post-heat treatment after erection should be explored. Post-heating an insulated tank may be possible if an ample source of heat is readily available and if the rigidity of the tank is adequate.
The thermal stress-relief treatment performed on pressure vessels is recognized as a means for reducing the probability of brittle failures.

The most popular standards for API Std 650 ground supported liquid storage tanks are API Std 650, JIS B8501, BS2654, GB50341, etc. The formulas used in each standard are derived from the hoop stress calculation formula of membrane theory. Combined with the stress characteristics of API Std 650 ground supported liquid storage tanks, plus the allowable stress, weld coefficient and additional wall thickness, the wall thickness calculation formula is complete. The allowable stress and weld coefficient are determined according to the material performance characteristics and construction technology level of each country. According to different API Std 650 ground supported liquid storage tanks standards, the calculation results of tank wall thickness are sometimes quite different.