API Std 650 storage tank subject to a small internal pressure

Density of API Std 650 storage tank Liquid Stored
The density of the liquid stored shall be its maximum density within the range of design temperatures, but no less than 29.3 lbf/ft3 for methane, 34.21 lbf/ft3 for ethane, and 35.5 lbf/ft3 for ethylene.
Design Metal Temperature
The design metal temperature of each component exposed to the liquid or vapor being stored shall be the lower of the temperatures specified as follows: The design metal temperature of the components of the API 620 single-wall tank or the inner tank of a double-wall tank shall be the minimum temperature to which the tank contents shall be refrigerated, including the effect of subcolony at reduced pressure.

For open top and fixed roof API 650 tanks, the net working capacity is the liquid volume contained between the minimum operating level (top of API 650 tanks API Std 650 storage tank outlet connection) and the maximum operating level [limited to the bottom of overflow connection, 75 mm below foam chamber connection, or 150 mm below rim, whichever is greater.

In year 2015, we ship 750 tons H beam to Pakistan for our old customer for building use. Because of urgent demand, the H beams are partial shipment by bulk vessel. Due to strong support of our customer, we also export many C channel steel, API Std 650 storage tank I beam and other profile steel to local market.

}

The foundation design of the API Std 650 storage tank should meet the requirements of foundation stability and deformation, that is, the API Std 650 storage tank foundation should not be crushed and the uneven settlement value of the foundation should be within the allowable range. The uneven settlement of the storage tank foundation should be specified in the design process of the safe allowable range, because excessive uneven settlement will reduce the safety of the API Std 650 storage tank and cause distortion and deformation of the tank wall and bottom plate.

If customers have any difficult problems during use of the steel materials, they can contact the company's after-sales service department to feedback the existing problems. The after-sales department will reply as soon as possible to ensure that each customer has a good after-sales experience. Under special circumstances, the after-sales service department will start the problem-solving process, and the engineers in charge of the area will quickly follow up to solve the problem.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!