API Std 650 self-anchored flat-bottom steel tanks larger than 50 ft in diameter
Our company has sales department, technology department, quality inspection department, after-sales department, logistics department. Each department has professional knowledge and high professional quality, put customers first, think about the interests of customers, actively communicate with customers and solve problems smoothly.
Requirements for prefabrication of the top of large vertical API Std 650 self-anchored flat-bottom steel tanks: The prefabrication of the tank top shall be prefabricated in blocks according to the drawings. Pay attention to the spacing of the welds after installation when setting out the material. Reinforcing ribs should be formed and inspected with an arc-shaped template. When a single top plate needs to be spliced, butt joints should be used. The forming of a single top plate should be welded between the reinforcing ribs and the top plate on the mould. After forming, check with an arc-shaped sample plate, and the gap should not be greater than 10 mm.
Large Steel storage tank AnchorageIn addition to the loads in API 620 oil storage tank Q.4, Q.5.1, and Q.5.2, the anchorage for the tank that contains liquid, whether it be a single-wall tank or the inner tank of a double-wall tank, shall be designed to meet the requirements of Q.3.6.2 through Q.3.6.5. The anchorage shall accommodate movement of the tank wall and bottom caused by thermal changes. For anchored flat-bottom tanks, the anchorage shall be designed as described in Q.3.6.4.1 through Q.3.6.4.3.