API Std 650 open-top tanks vacuum breaker vent
Lateral braces between outer bay rafters must be provided if asymmetrical structural shapes are used for rafters and if the API Std 650 open-top tanks API 650 tanks are located in areas subject to earthquakes. The bracing must be adequately sized for the seismic zone specified.
To the society: With the development of the company, BEBON has always adhered to the development mission of "developing heavy industry for the benefit of all mankind; improving the environment and achieving sustainable development”, operating with integrity and paying taxes in accordance with law.For our employees, the company fully respect employee value, pursuing mutual development of enterprise and employees.
Allowable compressive stresses shall be in accordance with 5.5.4 except that for aluminum alloy plate the allowable compressive stresses shall be reduced by the ratio of the modulus of compressive elasticity to 29,000 for values of (t – c)/R less than 0.0175 and by the ratio of the minimum yield strength for the aluminum alloy in question to 30,000 for values of (t – c)/R equal to or greater than 0.0175 (see 5.5.2 for definitions). In all other equations in this standard API Std 650 open-top tanks where yield strength or modulus of elasticity is used, such as Equations 27 and 28, similar corrections shall be made for aluminum alloys.