API Std 650 mechanically-anchored tanks design spectral response accelerations

API 620 Crude Oil Tank Non-pressure Parts
Welds for pads, lifting lugs, and other nonpressure parts, as well as temporary lugs for alignment and scaffolding attached to primary components, shall be made in full compliance with a welding procedure qualified in accordance with Q.6.1. Lugs attached for erection purposes shall be removed, and any significant projections of API Std 650 mechanically-anchored tanks weld metal shall be ground to a smooth contour. Plate that is gouged or torn in removing the lugs shall be repaired using a qualified procedure and then ground to a smooth contour. Where such repairs are made in primary components, the area shall be inspected by the liquid-penetrant method. A visual inspection is adequate for repairs in secondary components.

API 650 external floating roof storage tanks are generally called external floating roof API Std 650 mechanically-anchored tanks tanks, which means that the storage tanks are externally open tanks without a dome design, and are equipped with vertical floating roofs. API 650 external floating roof storage tanks are usually used for large More than 20,000 cubic meters of open steel API Std 650 mechanically-anchored tanks storage tanks for storing volatile petroleum products such as crude oil, gasoline, kerosene, etc.

On September 14th 2019, a Australia customer purchased 500 tonsDIN17155 15Mo3 boiler steel plates, which will be used for vessel modification of wax backflow protection project and LPU project. Many old customers keep asking about Din17155 steel grade-15Mo3. Usually our company would suggest customers to choose EN10028 steel specification, but if customer insiste on the old steel grade, we could arrange it either. With years of experience in produceing DIN 17155 15Mo3 boiler steel plates, the company supplies high quality steel API Std 650 mechanically-anchored tanks product with low cost and better service.

}

The mechanical seal of floating roof API Std 650 mechanically-anchored tanks relies on mechanical force to press the sealing steel plate tightly against the tank wall, so that it can slide on the tank wall and avoid gap as far as possible. However, mechanical seal has high requirements for the geometry of storage tank and poor adaptability, so mechanical seal is rarely used in newly built floating roof API Std 650 mechanically-anchored tanks.

We should focus on the main problems to be solved and pay attention to efficiency. After receiving the user's quality objection report data, the possible causes, responsible units, compensation amount, etc. of the problem shall be judged based on experience. To have a clear service plan, to be clear about what your main problem is, what technical support is needed, these should be prepared.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!