API Std 650 mechanically-anchored steel tanks flanges
Deformation of the welding seam of the API Std 650 mechanically-anchored steel tanks is a common quality problem during the actual use of the API Std 650 mechanically-anchored steel tanks, which easily causes the tank body to leak and affects the safety of the oil storage tank. The welding seam deformation of the API Std 650 mechanically-anchored steel tanks is mainly caused by the lack of reserved welding seam gap and irregular operation. The oil storage tank has not reserved the corresponding weld gap, resulting in deeper root removal during the front welding activity. The heat output of the weld will increase under the influence of a long time, and the deformation of the weld will gradually become serious.
Materials for API Std 650 mechanically-anchored steel tanks primary components shall comply with the requirements of Tables R-1 and R-2. All primary components shall be impact tested in accordance with R.2.1.2 through R.2.1.4. Impact testing of API 620 welded storage tanks plates, including structural members made of plate, shall comply with Table R-1. Impact test specimens shall be taken transverse to the direction of final plate rolling.
Large net shell API 650 tanks or net shell of tank API Std 650 mechanically-anchored steel tanks is a tank top for the surface grid structure and the physical structure form of truss structures, thin shell structure is reasonable, mainly for the top using triangle net shell, socket type net shell or meridian reticulated shell technology for the design of API Std 650 mechanically-anchored steel tanks large-scale tank top, its great spanning capacity and uniform stress, good rigidity, less material, convenient assembly, safe and reliable.