API Std 650 liquid-storage tanks design metal temperature

API 620 Tank Design
The designer of these large tanks API Std 650 liquid-storage tanks shall supply the data on superimposed loadings to be assumed for the foundation design or, if there are no foundations, for direct loading on the subgrade. A slab or mat may be provided to support the superstructure and shall be considered to distribute the load more evenly over a lower natural subgrade compared with merely stripping, leveling, and rolling the existing grade.
For simple spheroids or tanks of similar design, in which the distribution of the imposed weights shifts because the liquid level in combination with the vapor pressure may change the shape of the tank, the designer shall consider the possibility of such a change.

Corrosion allowance, if specified, shall be added to calculated API 650 tanks shell and self-supporting roof thicknesses; to minimum nominal thicknesses of bottom and supported API Std 650 liquid-storage tanks roof plates; to nozzles and manholes; and to all exposed surfaces of internal structural members and non-removable internals.

In 2015 , We get the tender from Myanmar Government, the total quantity is 1200 ton ABS-AH36 steel plate, we supply the steel plate with painting ( which standard is according to ISO SA2.5) with gray Color 20 Micron. After Get Customer Contract, Steel Plate Are Produced within 25 days .Then, Goods transported to Tianjin Port And Shipping On Time To Statisfy With Project Expected After Finished Producing. The Steel Quality API Std 650 liquid-storage tanks we offered receive good Praise from our Customers .

}

The cone slope of the completed API Std 650 liquid-storage tanks foundation is 15/1000 for the general foundation and less than 35/1000 for the soft foundation. After the foundation settlement of the storage tank is basically stable, the surface slope must be greater than eight thousandths. The edge of the tank bottom should be more than 0.3 meters higher than the surrounding ground. Above the ground, the tank bottom leakage detection tube should be drawn from the foundation sand cushion and cross the foundation ring wall or the slope protection surface. The circumferential distance should be less than 20 meters, and each API Std 650 liquid-storage tanks should have at least 4 detection tubes.

Responsibilities: dealing with quality feedback and complaints from Customer.Bebon has the after sale service department, which is responsible to solve the problem of technical support and quality, service complaints. You can also contact the company customers service online if you have any problem when you receive the products. The responsibility is to deal with quality feedback and complaints from Customer. Welcome to come and visit our company office.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!