API Std 650 ground supported tanks for elevated temperature service
Generally, the snow load in the API Std 650 ground supported tanks construction area should be considered before the design and construction of the tank. The snow load in the API Std 650 ground supported tanks construction area has an impact on the tank roof design and operation, especially in the area with large snow load, the roof load of large storage tank with large diameter increases. Anti freezing, heat preservation and waterproof measures shall be taken for the additional facilities of storage tanks, such as pumps, breathing valves, flame arresters, detection instruments and thermal insulation layers.
The company's after-sales service tenet is "customer first, timely guarantee, enthusiastic service and effective work". In order to establish a set of perfect after-sales service system and strict management system, so that the after-sales service can be effectively guaranteed. The company has set up after-sales service department to ensure timely, unique and effective response to every user's request, coordinate internal resources internally, and put an end to all evasion and delay.
Test plates shall be welded using the same qualified welding procedure and electrodes that are required for the tank shell plate joints. The API 620 steel storage tank test plates need not be welded as an extension of the tank shell joint but shall be welded in the required qualifying positions. One test weld shall be made on a set of plates from each specification and grade of API Std 650 ground supported tanks plate material, using a thickness that would qualify for all thicknesses in the shell. Each test welded of thickness t shall qualify for plate thicknesses from 2t down to t/2, but not less than 5/8 in. For plate thicknesses less than 5/8 in., a test weld shall be made for the thinnest shell plate to be welded; this test weld will qualify plate thicknesses from t up to 2t.
Pipeline transportation of API 650 oil tank is not less than the maximum consumption of 3 to 5 days. The daily operating time of API Std 650 ground supported tanks office buildings and fuel oil equipment is 12-16 hours; for high-end residential hotel buildings, the daily operating time is 16-24 hours.