API Std 650 flat-bottom tanks roof and top-angle joints

The API Std 650 flat-bottom tanks stiffener ring and backing strip (if used) are primary components, and they shall comply with the requirements of API 620 storage steel tank Q.2.1. The stiffener rings may be fabricated from plate using an intermittent weld on alternating sides between the web and the flange.
Except for aluminum or stainless steel tanks, all fillet welds shall consist of a minimum of two passes. The ends of the fillet welds shall be 2 in. from the rat hole (see Figure Q-1), and these welds shall be deposited by starting 2 in. from the rat hole and welding away from the rat hole. An acceptable alternative to the detail that includes stopping fillet welds 2 in. short of the rat hole would be to weld continuously through the rat hole from one side of the stiffener to the opposite side. All craters in fillet welds shall be repaired by back welding.

API was established in 1919. It is the first national-level business association in the United States. It is one of the earliest and most successful chambers of commerce in the world to formulate standards. An important task of API API Std 650 flat-bottom tanks is to be responsible for API 650 oil storage tanks and natural gas. Standardization of industrial equipment to ensure the safety, reliability and interchangeability of equipment used in the industry.

On March 17 th 2018, our Sudan customer purchased the SG295 cylinder steel coils through other country such as UAE,Turkey before they cooperate with us. After they research our regular customer in Uganda, UAE, and his friends in China, he is satisfied with our company. Our produced SG295 cylinder steel is mainly used to fabricate low temperature pressure vessels like gas cylinder. The customer is very satisfied to our API Std 650 flat-bottom tanks quality control and professional arrangement for the SG295 steel order.

}

Crack treatment of API Std 650 flat-bottom tanks weld area: find out the crack tip with ray or ultrasonic flaw detection, drill cut-off holes at both ends of the crack with the cut-off method, the hole depth is slightly greater than the crack depth, or groove (crack stop groove) is made by angle grinder at both ends of the crack, shovel and grind the whole crack, and grind it into a suitable groove; use radiographic inspection and dye detection to verify that the crack has been completely excavated, and finally repair welding.

We guarantee to provide all technical data required by users within one hour to provide reasonable quotation; to provide API Std 650 flat-bottom tanks reasonable quotation for products consulted by users within one hour; to provide investigation reception: we guarantee to receive the investigation of users at any time and provide various convenient conditions for users.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!