API Std 650 fixed roof tanks roof and top angle joints
API 650 is the standard for welded tanks for oil storage. It specifies the API Std 650 Fixed roof tanks design, manufacturing, welding, inspection and installation requirements of oil tanks. API 650 is widely used in storage tanks with internal pressure less than or equal to 2.5 PSI.
The bottom plate of the vertical API Std 650 fixed roof tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API Std 650 fixed roof tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.
Impact Test Requirements for Oil Storage Tanks Primary ComponentsAll API Std 650 fixed roof tanks primary components of 9% or 5% nickel steel shall be impact tested in accordance with Q.2.2.2 through Q.2.2.4. Impact testing is not required for primary components of austenitic stainless steel, nickel alloy, and aluminum materials. Welds in high-alloy (austenitic) stainless steel shall be impact tested if required by Q.6.3.Impact testing of plates, including structural members made of plate, shall comply with the following:a)Impact test specimens shall be taken transverse to the direction of final plate rolling. b)Charpy V-notch specimens shall be cooled to a temperature of –320°F for A353, A553, and A645 steels for impact testing.
For employees' development, the company's transformation and development provides employees with a broad career development platform. The company needs "lion-type" entrepreneurial leaders who are full of entrepreneurial enthusiasm and dare to self-renovate. They also need a large number of professional and professional high-quality talents, and employees can get full capacity to display opportunities.
Booking space and making power of attorney (ten copies of order); the data of the original order shall be correct and consistent to the greatest extent when making the order, so as to reduce the frequent changes in the subsequent process. For booking with the company's seal for booking space, if the accessories for booking space (such as the price confirmation document of the shipping company) need to be provided, they can only be booked with all of them. Obtain the shipping space allocation receipt and extract the ship name, voyage number and B / L number information.