API Std 650 cylindrical welded storage tanks NPS 8 sample hatch
API 650 is used to store products such as crude oil, gasoline, chemicals, and produced water. BBN has extensive experience in API Std 650 cylindrical welded storage tanks API 650 tanks with diameters between 8'-300', which are suitable for refineries, terminals, pipeline facilities and other projects.
Company management philosophy: integrity-based, service-oriented, excellence, affinity symbiosis. Based on quality, continuously create maximum value for customers. Always have a grateful heart, thank the society, thank family and friends for their support and help to the development of the company, thank customers for their trust, thank colleagues for their cooperation, and thank competitors for their supervision.
In this project, an elemental area of tank wall used is constructed of ASTM A442 Grade 55 steel plate subjected to a meridional unit force, T1, of 4000 lbf/in.2 tension and a latitudinal unit force, T2, of 5060 lbf/in.2 compression. The meridional radius of curvature, R1, is 75 in., and the length of the normal from the surface to the axis of revolution, R2, is 300 in. The joints in the wall are of double-welded butt-joint construction with a tensile efficiency of 85%. A corrosion allowance of 1/16 in. is required.The problem in this example is to graphically find the minimum thickness of tank wall required for the given conditions (see 5.10.3.3).Solution: As determined from Table 5-1, the maximum allowable tensile stress value, Sts, for ASTM A442 Grade 55 steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R in this situation is R1, or 75 in.