API Std 650 aboveground steel oil storage tanks structural shapes

Stamping of API 620 storage tank PlatesBefore plates required to be stamped by the steel mill are used, the inspector shall see that they bear the stamp. In laying out and cutting the API Std 650 aboveground steel oil storage tanks plates, at least one set of the original material identification markings should, if possible, be left where it will be plainly visible when the tank is completed. Should the identifying marks be obliterateSpot radiographic or ultrasonic examination shall be not less than 6 in. extending along the weld. Spot radiography shall comply with the standards given in 7.15.1.3. Where spot radiographic or ultrasonic examination is applied at joint intersections, the surface shall be prepared and examined for a distance of 3 in. on each side of the intersection, making the minimum length of examination 6 in. on the horizontal weld and 3 in. on the vertical weld.

The vent pipe mouth should be 4m or more above the ground. The nominal diameter of the API Std 650 aboveground steel oil storage tanks API 650 petroleum storage tank vent pipe should be no less than 50mm and a flame arrestor should be installed.

In the year of 2015, customer from Peru oil refinery contact with us from Internet. After one month’s negotiation and quotation, they chose us as there supplier of raw steel plate API Std 650 aboveground steel oil storage tanks grade ASTM A36. We get an trail order of 300 tons in April. When the first ship arrived, they inspect the steel plate and very happy with the quality we supply. Then they put another 1700 tons order, we sent to them within 90 days. Our company management group visit the customer in the beginning of 2016 and the visit is very successful.

}

Inspection of API Std 650 aboveground steel oil storage tanks bottom: magnetic flux leakage scanning technology is used to detect the corrosion condition of API Std 650 aboveground steel oil storage tanks bottom plate (such as corrosion depth and area, crack length, etc.). When there is a defect in the bottom plate of the API Std 650 aboveground steel oil storage tanks, the magnetic field distribution will change and the sensor can detect it. The bottom of the oil tank should be free of foreign matters and dry during testing. Weld inspection of API Std 650 aboveground steel oil storage tanks bottom plate: when vacuum leak test method is used to detect the tightness of oil tank bottom plate, soap water shall be applied to the weld and vacuum box shall be covered for observation.

The after-sale service of iron and steel products includes after-sale tracking service, technical guidance, transfer of relevant bills, handling of objections and many other contents. The handling of quality objections accounts for a large proportion. When dealing with these problems, we should distinguish the responsibilities, and compensate or return the inconvenience or loss caused to users due to steel.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!