API standard 650 self-anchored tanks internal structures

The API standard 650 self-anchored tanks external floating roof tank of API 650 tank has many advantages, and its application range is more and more wide. It is a kind of storage tank with a bright future. The well-designed internal floating roof tank of API 650 tank is the best and least investment method to control evaporation loss of API standard 650 self-anchored tanks Fixed roof tank.

As steel transportation belongs to the transportation of major parts, so in the process of transportation, modern logistics technology, such as centralized transportation, information technology, is a bit out of place. Based on the current situation of China's API standard 650 self-anchored tanks steel transportation industry, highway transportation is a way of transportation that many enterprises often choose. Naturally, its business volume also accounts for more than 50% of the whole API standard 650 self-anchored tanks steel transportation industry.

In this project, an elemental area of API 620 oil storage tank wall is constructed of ASTM A516 Grade 55 steel plate subjected to a meridional unit force, T1, of 2620 lbf/in. tension and a latitudinal unit force, T2, of 2880 lbf/in. compression. The meridional radius of curvature, R1, is 132 in., and the length of the normal from the surface to the axis of revolution, R2, is 409 in. The joints in the wall are spot-radiographed, double-welded butt joints, and no corrosion allowance is required.
The problem in this example is to graphically find the minimum thickness of tank wall required for the given conditions (see API 620 tank standard 5.10.3.3).
Solution: As determined from Table 5-1, the maximum, allowable tensile stress value, Sts, for ASTM A516 Grade 55 steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R for this situation is R1, or 132 in.

When encountering heavy rain or continuous heavy rainfall, the safe operation of API standard 650 self-anchored tanks will be affected. For example: the API standard 650 self-anchored tanks is submerged, the oil unloading valve and the flame arrester valve are broken by water and the oil tank leaks. The oil tank area must do emergency work to prevent rainstorm to ensure the safety of the oil tank. Here are some safety protection measures for API standard 650 self-anchored tanks in heavy rain.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.