Soil Structure Interaction: Soil structure interaction per API 650, Section E.6.1.6 may be used for OLE design providing the damping ratio does not exceed 10 %.
Allowable Stresses
Design allowable stresses shall be per API 620 large welded steel storage tank, Section Q.3.3, including the 33 % increase permitted for earthquake loads.
Self-anchored Inner Tank
The anchorage ratio for a self-anchored inner tank, J, shall not exceed 1.0 for the OLE design combination to limit uplift and stresses in the annular plate and corner weld.
Foundation Stability
The overturning ratio defined in API 650, Section E.6.2.3, Equation (E.6.2.3-1) shall be equal to or greater than 3.0 for the defined OLE event.

The API 650 specification provides guidelines for the API standard 650 self-anchored flat-bottom tanks design, manufacturing, materials, installation and inspection of welded vertical and cylindrical tanks. Such containers must be on the ground and have a closed or open top.

In 2015 , We get the tender from Myanmar Government, the total quantity is 1200 ton ABS-AH36 steel plate, we supply the steel plate with painting ( which standard is according to ISO SA2.5) with gray Color 20 Micron. After Get Customer Contract, Steel Plate Are Produced within 25 days .Then, Goods transported to Tianjin Port And Shipping On Time To Statisfy With Project Expected After Finished Producing. The Steel Quality API standard 650 self-anchored flat-bottom tanks we offered receive good Praise from our Customers .

}

The engineering quality of API standard 650 self-anchored flat-bottom tanks not only affects production and operation, but also affects the life safety of the staff. The factors affecting the API standard 650 self-anchored flat-bottom tanks construction quality are all aspects, any link, any part of the problem will affect the whole project, so the quality management is paid more and more attention. How to ensure the engineering construction quality of oil tank? First, make API standard 650 self-anchored flat-bottom tanks construction technical preparation carefully, understand the design intent, master the construction acceptance specification, and make detailed construction technical disclosure to the construction team.

The results of adopting two-level API standard 650 self-anchored flat-bottom tanks service system and implementing standardized management are mainly reflected in the formation of vigorous work style such as quick response and quick action. Our company's customer service center stipulates that employees must be accurate and quick in technical support and API standard 650 self-anchored flat-bottom tanks after-sales service. Through the formation of this fast, agile, vigorous style, to provide users with satisfactory service.