Charpy V-notch specimens shall be taken from the weld metal and from the heat-affected zone of the welding procedure qualification test plates or from duplicate test plates.
Weld metal impact specimens shall be taken across the weld with the notch in the API 620 oil tank material weld metal. The specimen shall be oriented so that the notch is normal to the surface of the material. One face of the specimen shall be substantially parallel to and within 1/16 in. of the surface.For open top and fixed roof API 650 tanks, the net working capacity is the liquid volume contained between the minimum operating level (top of API 650 tanks API standard 650 partially anchored liquid-storage tanks outlet connection) and the maximum operating level [limited to the bottom of overflow connection, 75 mm below foam chamber connection, or 150 mm below rim, whichever is greater.With the fast development in Myanmar, Myanmar navy build frigate every year. Bebon Cooperate with Myanmar Navy from from 2015. They purchased 412 ton API standard 650 partially anchored liquid-storage tanks LR AH36 steel plate from Bebon as trial order in 2015. After receiving the goods, they speak highly of the quality and bebon's service. After that they purchase the shipbuilding steel plate from bebon regularly. In May,2018, the Myanmar navy's local representative visit our office and production line, and sign another contract 2025 tons API standard 650 partially anchored liquid-storage tanks LR A shipbuilding steel plates order in our office.Inspection of weld and micro crack of API standard 650 partially anchored liquid-storage tanks: the inner and outer surface of API standard 650 partially anchored liquid-storage tanks, weld and heat affected zone shall be observed by naked eyes first. 100% ultrasonic testing or 100% penetrant testing are carried out for butt welds of API standard 650 partially anchored liquid-storage tanks. For the defects found by 100% magnetic particle inspection, dye detection, 100% ultrasonic inspection or 100% penetrant inspection, the radiographic inspection shall be used again to ensure the accuracy of the test results.The company's after-sales service tenet is "customer first, timely guarantee, enthusiastic service and effective work". In order to establish a set of perfect after-sales service system and strict management system, so that the after-sales service can be effectively guaranteed. The company has set up after-sales service department to ensure timely, unique and effective response to every user's request, coordinate internal resources internally, and put an end to all evasion and delay.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!