API standard 650 open top welded storage tanks allowable stresses
API 620 Crude Oil Tank Non-pressure PartsWelds for pads, lifting lugs, and other nonpressure parts, as well as temporary lugs for alignment and scaffolding attached to primary components, shall be made in full compliance with a welding procedure qualified in accordance with Q.6.1. Lugs attached for erection purposes shall be removed, and any significant projections of API standard 650 open top welded storage tanks weld metal shall be ground to a smooth contour. Plate that is gouged or torn in removing the lugs shall be repaired using a qualified procedure and then ground to a smooth contour. Where such repairs are made in primary components, the area shall be inspected by the liquid-penetrant method. A visual inspection is adequate for repairs in secondary components.
The API 650 is the American standard for welded flat-bottomed vertical API standard 650 open top welded storage tanks storage tanks. This standard dictates tank design, manufacture, welding, inspection and installation requirements.
The Seamless Pipe Q345D to Thailand. In November of 2015, Thailand OTTO group contacted with us from Internet. They are finding the trustable supplier of S355/2H seamless pipe for the cable car supporter. Due to the special using of the pipes, they are very careful and serious when choosing the supplier. After one months contact and discussion by email, they come to our company. We drive to the pipe mill for visit of 2 days. Through this visit, they are very confident with our production ability and products quality. Finally, they accept the grade we suggest Q345D. After back to office, they put the order of 1800 tons pipe to us directly.
}The structure of the API standard 650 open top welded storage tanks foundation mainly includes the insulating anticorrosion layer on the top surface of the foundation, the tank wall support, the edge retaining structure, the sand cushion, the oil and water barrier, the detection signal tube and other structures. The construction materials and requirements of each basic structure of the storage tank are different. After the structure of the API standard 650 open top welded storage tanks foundation is built in accordance with the construction requirements, the settlement of the storage tank foundation needs to be observed, and the uneven settlement value of the storage tank foundation should be within the allowable safety range.
Respect customers and treat each other sincerely. Customers are always right. Always remember that the user is the God of the enterprise, respect the customer, and accept the customer's opinion modestly is the guarantee of the long-term development of the enterprise. Adhere to this concept, so that the service and the product are the same, long-term.