API standard 650 liquid storage tanks welding symbols
Impact Test Requirements for Oil storage tanks Primary ComponentsAll API standard 650 liquid storage tanks primary components of 9% or 5% nickel steel shall be impact tested in accordance with Q.2.2.2 through Q.2.2.4. Impact testing is not required for primary components of austenitic stainless steel, nickel alloy, and aluminum materials. Welds in high-alloy (austenitic) stainless steel shall be impact tested if required by Q.6.3.Impact testing of plates, including structural members made of plate, shall comply with the following:a)Impact test specimens shall be taken transverse to the direction of final plate rolling. b)Charpy V-notch specimens shall be cooled to a temperature of –320°F for A353, A553, and A645 steels for impact testing.
Before pressure test, the main drain hose system of API 650 petroleum storage tank floating roof should be thoroughly flushed. Provide blind flanges, gaskets and bolts required for the API standard 650 liquid storage tanks test (other types of covers are also required if necessary). Covers for maintenance shall be provided in accordance with the interfaces specified by API 650 petroleum storage tanks, and these seals shall remain in place after the test; and for those interfaces that are not provided for maintenance covers, the covers can be removed after the API standard 650 liquid storage tanks test.
In year 2015, we supplied 950 tons S355J0 angle steel to Egypt government. We have cooperation with local government for more than 3 years. Every year, they would order more than 3000 tons of API standard 650 liquid storage tanks steel from our company.
}API standard 650 liquid storage tanks construction must adhere to the design drawings, acceptance specifications and construction plans. If the design needs to be modified during API standard 650 liquid storage tanks construction, it must be approved by the original design unit or Party A’s representative and relevant personnel of the supervision unit, and written visa procedures must be completed in advance. The equipment and main materials used in the oil tank construction project must have certificates of conformity and quality assurance.
Before delivering our hot rolled plate product we apply various tests to check the quality of carbon steel API standard 650 liquid storage tanks plates such as- mechanical test, chemical test, hardness test, toughness test, eddy current test, impact test, micro test, flaring test, flattening test, etc. We are provided best packing for structural steel plates to avoid rust. Our after-sales service team will contact you if you have any question.