API standard 650 liquid storage tanks qualification of welding procedures
API standard 650 liquid storage tanks Pressure-relieving DevicesTanks shall be protected by automatic pressure-relieving devices that will prevent the pressure at the top of the tank from rising more than 10% above the maximum positive gauge pressure except as provided in API 620 standard 9.2.2.Where an additional hazard can be created by the exposure of the tank to accidental fire or another unexpected source of heat external to the tank, supplemental pressure-relieving devices shall be installed. These devices shall be capable of preventing the pressure from rising more than 20% above the maximum positive gauge pressure. A single pressure-relieving valve may be used if it satisfies the requirements of this paragraph and 9.2.1.
Prevent the storage liquid from impacting the inner wall of the API 650 petroleum storage tank or increase the internal pressure, reduce the corrosion of the tank top and the tank wall, and extend the service life of the API standard 650 liquid storage tanks storage tank.
We exported 2150 Tons SG295 steel coils to Sudan. The Sudan customer is LPG cylinder manufacturer. Before our cooperation, he usually purchased SG295 steel coils from UAE and Turkey. And he got to know our company through our regular customers in Uganda, UAE, and his friends in China. Then he gave us the order. We invited the customer to visit us before contract, but he insisted to visit us when the API standard 650 liquid storage tanks goods are finished production. After inspecting the size, package in workshop and witness the lab test for the SG295 steel coils, the customer was very satisfied to our quality control and professional arrangement.
}Usually, the wind load in the API standard 650 liquid storage tanks construction area should be considered before the tank design and construction. The wind load in the API standard 650 liquid storage tanks construction area has an impact on the stability and economy of the API standard 650 liquid storage tanks. In the area with large wind load, it is safe to design the tank as "squat". When calculating the wind force, the influence of the thickness of the insulation layer of the API standard 650 liquid storage tanks, the shape of the ladder, the platform, the pipeline and the top cover must be considered.
Provide special product requirements to meet the personalized needs of customers. The API standard 650 liquid storage tanks company arranges production and shipment strictly according to the contract, and guarantees to supply goods according to the time agreed in the contract. Provide professional consultation: we guarantee to answer any professional and API standard 650 liquid storage tanks technical questions raised by users within 1 hour; provide detailed information.