API standard 650 liquid storage tanks platforms, walkways, and stairways
For the team, cooperation is the core idea of daily work, and the core of common cooperation is resource sharing. With a perfect resource sharing mechanism, the whole team can be called a unity spirit.A good team lies in the ability to transfer resources, knowledge and information in time among team members in order to achieve the common goals of the team. So that we can share experiences and lessons."Pressure Setting of Safety DevicesExcept as provided in API 620 tank 9.5 for certain liquid relief valves, the pressure setting of a pressure-relieving device shall in no case exceed the maximum pressure that can exist at the level where the device is located when the pressure at the top of the tank equals the nominal pressure rating for the tank (see API 620 tank 5.3.1) and the liquid contained in the tank API standard 650 liquid storage tanks is at the maximum design level.Vacuum-relieving devices shall be set to open at such a pressure or partial vacuum that the partial vacuum in the tank cannot exceed that for which the tank is designed when the inflow of air (or other gas or vapor) through the device is at its maximum specified rate.The inner layer of API 650 tank is the same as that of single layer tank. It is made of high-quality steel plate in strict accordance with the standard of "steel welded atmospheric pressure vessel". The thickness of API standard 650 liquid storage tanks steel plate reaches the standard and the service life is longer.Enterprise Motto:Integrity, harmony, dedication, innovation and developmentAbility is the cornerstone of success; action is the ladder of successGrow with the enterprise; progress with the enterpriseGive a platform to those who actually do things and a stage to those who successfully do thingsDare to be the first, to pursue excellence.The most popular standards for API standard 650 liquid storage tanks are API Std 650, JIS B8501, BS2654, GB50341, etc. The formulas used in each standard are derived from the hoop stress calculation formula of membrane theory. Combined with the stress characteristics of API standard 650 liquid storage tanks, plus the allowable stress, weld coefficient and additional wall thickness, the wall thickness calculation formula is complete. The allowable stress and weld coefficient are determined according to the material performance characteristics and construction technology level of each country. According to different API standard 650 liquid storage tanks standards, the calculation results of tank wall thickness are sometimes quite different.
Latest NewsMore+