Soil Structure Interaction: Soil structure interaction per API 650, Section E.6.1.6 may be used for OLE design providing the damping ratio does not exceed 10 %.
Allowable Stresses
Design allowable stresses shall be per API 620 large welded steel storage tank, Section Q.3.3, including the 33 % increase permitted for earthquake loads.
Self-anchored Inner Tank
The anchorage ratio for a self-anchored inner tank, J, shall not exceed 1.0 for the OLE design combination to limit uplift and stresses in the annular plate and corner weld.
Foundation Stability
The overturning ratio defined in API 650, Section E.6.2.3, Equation (E.6.2.3-1) shall be equal to or greater than 3.0 for the defined OLE event.

API 650 external floating roof storage tanks are generally called external floating roof API standard 650 aluminum tanks tanks, which means that the storage tanks are externally open tanks without a dome design, and are equipped with vertical floating roofs. API 650 external floating roof storage tanks are usually used for large More than 20,000 cubic meters of open steel API standard 650 aluminum tanks storage tanks for storing volatile petroleum products such as crude oil, gasoline, kerosene, etc.

Square hollow section S355J2H to Turkey. In January of 2015, our customer from Turkey chose us as their supplier of seamless RHS EN10219 S355J2H with a trail order of 120 tons. They required DNV test for the MTC and each tube. DNV inspector tested all the tubes and MTC. When our customer received the reports, they gave us a second order of 852.5 tons. Since then we maintain a long time cooperation relationship.

}

High temperature heat transfer oil fin tube heating device for large API standard 650 aluminum tanks has the advantage of reducing the leakage of heating coils. The heating medium of the large storage tank heating device is high-temperature heat-conducting oil. The boiling point of the heat-conducting oil is high, usually higher than 200°C. At high temperatures, the pressure on the heat-conducting oil circulation pipeline is very small, which greatly reduces the occurrence of heating coil leakage accidents. At the same time, the temperature difference between the inside and outside of the tube is guaranteed.

There is a careful, patient, enthusiastic and thoughtful after-sales team, a professional distribution, ultra-efficient warehouse and logistics center, a marketing team with marketing expertise, an innovative technology center with strong steel technology, an experienced manufacturing center with rigorous professionalism Quality Inspection Center, an operation team with many years of administrative management experience. Such a strong combination of teams makes BEBON a steel giant in Henan Province.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!