We have Business Department, Transportation Department, Document Department, Shipping Department, E-C department, Procurement Department, Finance Department, Human Resources Department, Administration Department, Logistics Department, After-sales so on Departments. Each department performs its own duties, unites and cooperates, and contributes its greatest strength to the overall operation of the company. So as to ensure the stable and sustainable development of the company.Impact Test Requirements for Oil storage tanks Primary Components
All API standard 650 aboveground oil storage tanks primary components of 9% or 5% nickel steel shall be impact tested in accordance with Q.2.2.2 through Q.2.2.4. Impact testing is not required for primary components of austenitic stainless steel, nickel alloy, and aluminum materials. Welds in high-alloy (austenitic) stainless steel shall be impact tested if required by Q.6.3.
Impact testing of plates, including structural members made of plate, shall comply with the following:a)Impact test specimens shall be taken transverse to the direction of final plate rolling. b)Charpy V-notch specimens shall be cooled to a temperature of –320°F for A353, A553, and A645 steels for impact testing.This API 650 tank standard does not present orstablish a fixed series of allowable tank sizes: instead, it s intended to permit the purchaser to select whatever size API standard 650 aboveground oil storage tanks tank may best meet his needs.we develop very well through those years even the external environment is not conducive to the whole steel industry. With the prosperity of our group, our company always bear its staff who contributes to its growth in mind, and always on the way to improve welfare and treatment. That makes us staff and work with pleasure. On the other way, they creat a better and stronger our group. That may be one of the key factors why we develop so rapidly those years. Here we can say proudly “we are family”.Oil tank is often used to store crude oil, diesel oil, gasoline and other oil. The main structure of API standard 650 aboveground oil storage tanks is composed of tank top, tank wall, tank bottom and accessories. The API standard 650 aboveground oil storage tanks should be inspected after the completion of construction, and the detection methods of different structure positions are different. Tank wall inspection: for the newly built oil tank, water filling test shall be conducted to check whether the tank wall is tight, and the appearance inspection shall be conducted for the tank wall plate and weld. Tank wall thickness detection: the oil tank wall thickness is mainly detected by ultrasonic wave, with high efficiency.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!