API standard 650 aboveground oil storage tanks bleeder vents
The advantages of API 650 floating roof tanks have obvious environmental and economic benefits: in a specific climate environment, according to historical data, the economic value of the API standard 650 aboveground oil storage tanks floating roof tanks in API 650 due to the reduction of oil and gas volatilization within 3-6 months is equivalent The installation and purchase cost of the API standard 650 aboveground oil storage tanks inner floating roof means that the cost of the inner floating roof can be recovered within half a year.
As we all know, steel pipes occupy more space in the process of transportation. If there is no good way of packing, the transportation cost for steel pipes will be a big expense. In view of this characteristic, our company is ingenious and adopts the nest package method to solve this problem perfectly. The premise of the nest package is that the diameters of the steel pipes are different, and the small diameter pipe is inserted in the large diameter pipe. This not only saves the volume, but also saves the transportation cost. It also reduces the loading and unloading workload by half, saves precious time, and enables customers to receive goods earlier.
We can process the steel materials according to your drawing. Or if you can not make drawing, please send us API standard 650 aboveground oil storage tanks specific data and requirements, our technical department can make design and drawing for you, and then confirm with your technician or engineer. If all is OK, our processing center will process the steel materials according to the drawing. So no matter what size and shapes you need, we can meet demands at the most time.
Preheating should be performed by heating and maintaining this heat in appreciable lengths of the joint to be welded, preferably using a strip burner with a mild flame rather than a harsh flame such as that from a cutting torch. Electrical strip heaters are available and have been found to be satisfactory. The preheat of 300°F should be checked with a temperature-sensitive crayon, or similarly accurate means, so that the steel 4 in. (or four times the API standard 650 aboveground oil storage tanks plate thickness, whichever is greater) on each side of the joint will be maintained at the minimum preheat temperature. Ring burners or heaters are recommended for nozzle and manway welds. At no time during the welding should the base metal fall below a temperature of 300°F.