API 650 storage tank emergency roof drains

In order to prevent the deformation of the bottom of metal vertical API 650 storage tank during welding, comprehensive control measures such as strict control of assembly geometry size, reasonable welding procedure, process control of welding deformation and rigid fixation are adopted during assembly welding. The specific methods are as follows:
1. Strictly control welding groove forming of API 650 storage tank.
2. Strictly control the size of tank welding seam assembly.
3. Define the welding sequence of tank bottom plate.
4. Reasonable distribution of welders.

When providing technical services on site, the after-sales personnel shall strictly abide by the safety rules and regulations of the construction site, consciously take safety protection measures (such as wearing safety helmet when entering the construction site), accept the supervision and management of the site; without permission on the construction site, they shall not dismantle, smear or damage any goods; the commissioning of contract goods shall be carried out under the supervision of the site supervisor If necessary, it shall be approved by the site supervisor or the person in charge of the project department.

The company focuses on quality building, continuously create greatest value for customers, and has achieved good economic and social benefits. With strong financial strength, advanced management experience, perfect sales services, strict quality purchase management system and science overall marketing means. We are willing to go hand in hand with you for common development. To be the best service provider for iron & steel products globally is our goal.

API 650 petroleum storage tank stipulates that if the thickness of the lower siding obtained by calculating the anti-overturning moment is greater than the thickness of the API 650 storage tank hydrostatic pressure test (both do not include the corrosion margin), the calculated thickness of the above siding required by the hydrostatic pressure is It should also be increased by the same proportion, unless special analysis is performed to determine the seismic overturning moment and corresponding stress at the bottom of each layer of API 650 petroleum storage tank wall.