API 650 petroleum storage tanks water drawoff sumps
Before pressure test, the main drain hose system of API 650 petroleum storage tank floating roof should be thoroughly flushed. Provide blind flanges, gaskets and bolts required for the API 650 petroleum storage tanks test (other types of covers are also required if necessary). Covers for maintenance shall be provided in accordance with the interfaces specified by API 650 petroleum storage tanks, and these seals shall remain in place after the test; and for those interfaces that are not provided for maintenance covers, the covers can be removed after the API 650 petroleum storage tanks test.
The bottom plate of the vertical API 650 petroleum storage tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API 650 petroleum storage tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.
In this project, an area of steel storage oil tank wall is constructed of ASTM A285, Grade C, steel plate that is 5/8-in. thick and has spot-radiographed, double-welded butt joints. The wall is subject to tension in a meridional direction and to compression in a latitudinal direction. The values of R1 and R2 at the point under consideration are 75 in. and 300 in. respectively. A corrosion allowance of 1/16 in. is required. The computed (meridional) tensile stress, stc, in the net thickness after deduction of the corrosion allowance is 6000 lbf/in.2.
Our company's business departments are a group of excellent and hard-working employees, who constantly carry out knowledge updating and steel knowledge training every day, only to provide better and professional services to customers.
The mode of iron and API 650 petroleum storage tanks steel logistics transportation is mainly intercontinental ocean shipping and inland rail transportation. European ports have been very mature after years of development, such as Hamburg in Germany, Rotterdam in the Netherlands and Antwerp in Belgium. Relying on the huge market of the European Union, these ports are positioned in the logistics distribution function of cargo distribution and large import and export, and play a great role in the transportation of API 650 petroleum storage tanks steel logistics.