API 650 partially anchored liquid-storage tanks decks

The floating roof is the top cover floating on the liquid level, so the sealing performance of API 650 partially anchored liquid-storage tanks API 650 oil storage tank is very important. The floating plate mainly adopts elastic packing, and at the same time, it is compressed with the wall of API 650 oil storage tank with pressure strip around, and fixed with the floating plate with bolts. After the API 650 partially anchored liquid-storage tanks floating plate is lowered to a certain position of about 1.8m, a prop will support the floating plate to keep it in position.

Tianjin warehouse mainly stores steel plates and steel pipes. The monthly replenishment is about 12000 tons. Our inventory cycle is short and flexible. Shanghai warehouse mainly stores API 650 partially anchored liquid-storage tanks ,steel plate and section steel. The average monthly purchase volume is about 15000 tons. The geographical location of the warehouse has greatly improved our performance in terms of transportation and delivery time.

Standard Hydrostatic and Pneumatic TestsAfter erection is completed and stress relieving, radiographic examinations, or other similar operations, as may be required, are performed, each tank shall satisfactorily pass a series of hydrostatic and pneumatic tests as prescribed in 7.18.2 through 7.18.6. Whenever a solution film is specified in this section to be applied to welding, linseed oil or another equivalent material for disclosing air leakage may be substituted. In freezing weather, linseed oil or a similarly suitable material shall be used.The attachment welding around all openings and their reinforcements in the walls of the API 620 tank shall be examined by the magnetic-particle method both inside and outside the tank API 650 partially anchored liquid-storage tanks. When the underside of a tank bottom rests directly on the tank grade (and is not accessible after erection), such examination of welding on the underside of the bottom and subsequent air testing may be omitted.

In order to prevent the deformation of the bottom of metal vertical storage tank, API 650 partially anchored liquid-storage tanks during welding, the number of welders should be reasonably distributed. When welding metal vertical API 650 partially anchored liquid-storage tanks, personnel and welding position shall be reasonably allocated according to the actual situation of welding personnel, and random welding is not allowed.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!