API 650 open top welded storage tanks preheating
Shell Stiffening Rings for Tanks That Contain LiquidInternal or external shell stiffening rings may be required to maintain roundness when the tank is subjected to wind, vacuum, or other specified loads. When API 650 open top welded storage tanks stiffening rings are required, the stiffener-to-shell weld details shall be in accordance with Figure Q-1 and Q.3.5.2 through Q.3.5.5.Three-plate laps or butt-weld junctions in tank bottoms shall be not closer than 12 in. from each other or from the butt-welds of the annular plates.Bottom plates, other than annular bottom plates for a 9% or 5% nickel steel or stainless steel tank that contains liquid, may have a minimum thickness of 3/16 in. exclusive of any specified corrosion allowance.
API 650 tank has the advantages of less load on the floating plate, simple and light structure, and can save the central drainage pipe and rotating floating ladder on the API 650 open top welded storage tanks floating plate. The materials for easy construction and maintenance and sealing parts can avoid aging due to sunlight.
our company offered 2950 ton A36 steel API 650 open top welded storage tanks plate to Philippines customer, which was used to build water supply project. It is the government project. The procurement with their project engineer come to China to discuss this project in middle of 2016. After checking the mill, they signed the contract with us. we supply the ASTM A36 Original Mill Test Certificate Stamped.
}Inspection of API 650 open top welded storage tanks bottom: magnetic flux leakage scanning technology is used to detect the corrosion condition of API 650 open top welded storage tanks bottom plate (such as corrosion depth and area, crack length, etc.). When there is a defect in the bottom plate of the API 650 open top welded storage tanks, the magnetic field distribution will change and the sensor can detect it. The bottom of the oil tank should be free of foreign matters and dry during testing. Weld inspection of API 650 open top welded storage tanks bottom plate: when vacuum leak test method is used to detect the tightness of oil tank bottom plate, soap water shall be applied to the weld and vacuum box shall be covered for observation.
Over the years, the company has strived for perfection, being well-received. By virtue of stable product performance, high-quality engineering effects and perfect service system, we have won the trust of many customers, and our engineering cases and after-sales service systems are spread all over the world. We regularly conduct quality tracking and return visits by phone and email, listen to customers' opinions, and continuously improve service quality.