API 650 liquid-storage tanks ultrasonic examination

Treatment of API 650 liquid-storage tanks welding defects:
1. Lack of fusion: once found, it should be shoveled and grinded off before re welding.
2. Incomplete penetration: over standard defects shall be removed and re welded. When welding on both sides, the shallow side of the groove can be grinded and shoveled to expose the welding root on one side, and then the welding is repaired.
3. Slag inclusion: over standard defects shall be removed and re welded.
4. Crater: weld to full after grinding.
5. Air hole: if the internal air hole exceeds the standard, it shall be welded again after being removed by grinding shovel, and the surface air hole shall be removed by grinding wheel and then repaired.

Our quality control department will do inspection for details of the steel materials API 650 liquid-storage tanks before delivery. We would invite the customer side to attend the inspection together. If they can not come, we will also take rich pictures for them to check. Meanwhile, we will publish inspection report and send them the PDF version. Besides, we accept any third party inspection such as SGS, BV, etc. And our quality control department will support the third party to inspect the steel materials smoothly and try our best to deliver the qualified steel materials to customers earlier.

With the development of China's market economy, the company vigorously implements the strategy of industrialization, internationalization and diversification, promotes the group operation, intensive development and lean management, and through a rich series of products and project portfolio as well as a complete operation network, Build the company into a modern enterprise with scientific development concept, continuous innovation vitality, excellent corporate culture, strong sense of social responsibility and international first-class competitiveness.

API 650 petroleum storage tank body design is mainly the design of tank bottom, API 650 liquid-storage tanks tank top and tank wall, and the design of tank wall is particularly important. As the main pressure bearing part of API 650 petroleum storage tank, the tank wall bears loads including liquid pressure, wind pressure, seismic load, opening stress, etc. The calculation of such loads is explained in detail in various API 650 liquid-storage tanks storage tank design standards. But in addition, the API 650 petroleum storage tank wall also bears the push-pull force and torque of the connected pipeline.