API 650 ground-supported liquid storage tanks bottom joints

There is a gap of 100 mm to 500 mm between the shell of API 650 crude oil storage API 650 ground-supported liquid storage tanks tank and the floating plate of external floating roof to ensure that there is no chuck during operation. Use API 650 ground-supported liquid storage tanks edge sealing system to reduce edge evaporation. The support legs of API 650 crude oil tank floating roof are usually movable and retractable and suspended in liquid.

Prefabrication requirements of API 650 ground-supported liquid storage tanks, large vertical storage tank wall panels:
1. The prefabrication of wall panel shall be processed in strict accordance with the requirements of the drawings, and inspection records shall be made.
2. After the wall panel is rolled, it should be placed on the platform for inspection with a template. In the vertical direction, use a straight-line template to check, the gap should not be greater than 2 mm, and in the horizontal direction, use an arc-shaped template to check, and the interval should not be greater than 4 mm.
3. When wall panels are rounded, attention should be paid to prevent irreversible plastic deformation caused by external forces. After rolling, it should be placed on the platform for inspection, and then placed on the prepared mold.

The company operates on the principles of fairness, objectivity, science, pragmatism and integrity. The management treats people with courtesy, takes sincerity as the standard management, dares to open up, unites and advances, carries on the past and makes unremitting efforts, seizes the good trend of economic development, strengthens exchanges with peers, makes friends with all walks of life, keeps pace with the times and creates greater brilliance of the enterprise, and makes its own contribution to the prosperity and development of the steel industry.

The hardness of the welds contacting these environments, including the heat-affected zones, shall be considered. The weld metal and adjacent heat-affected zone often contain a zone of hardness that is well in excess of a value of 22 on the Rockwell C scale and could be expected to be more susceptible to cracking than would unwelded metal. Any hardness criteria shall be a matter of agreement between the Purchaser and the API 650 ground-supported liquid storage tanks manufacturer and shall be based on an evaluation of the expected hydrogen sulfide concentration in the product, the possibility of moisture being present on the inside metal surface, and the strength and hardness characteristics of base metal and weld metal.

Have a question? Get a Free Consultation