API 650 ground supported liquid storage tanks automatic welding
Allowable Design StressesThe maximum allowable design stresses for the API 650 ground supported liquid storage tanks materials outlined in Q.2.1 shall be in accordance with Table Q-3.The values for the allowable design tensile stress given in Table Q-3 for materials other than bolting steel are the lesser of (a) 331/3% of the specified minimum ultimate tensile strength for the material or (b) 662/3% of the specified minimum yield strength, but they are 75% of the specified minimum yield strength for the stainless steel, nickel alloy, and aluminum materials. Allowable test stresses are based on the limitation of API 620 oil tank storage standard Q.8.1.3.
The calculated thickness of the above-mentioned wall panels required by the hydrostatic pressure is also It API 650 ground supported liquid storage tanks should be increased by the same ratio, unless special analysis is performed to determine the seismic overturning moment and the corresponding stress at the bottom of the wall of each layer of API 650 tank.
In December of 2015, our regular India customer sent us an inquiry for API 650 ground supported liquid storage tanks pipe. The inquiry requires no negative tolerance in both pipes’ outer diameter and pipe wall. After two weeks’ discussion, he put the order of 275 tons to us. The pipes are finished within just one month. Our customer come to our factory to inspect the quality and tolerance, all the products are well meet his demand. The pipes are arriving to Nhava Sheva port, customer is very happy with our products and service during the process.
}The main reason of "small breathing" loss of API 650 ground supported liquid storage tanks is the change of atmospheric temperature. When the temperature rises with the increase of solar radiation from dawn, the temperature of oil in the API 650 ground supported liquid storage tanks also changes, resulting in the acceleration of evaporation speed and the increase of evaporation pressure. When the pressure exceeds the positive pressure rating of the breathing valve, the oil-gas mixture in the API 650 ground supported liquid storage tanks is discharged into the atmosphere through the breathing valve, which is the "exhalation" process of the oil tank.
The company conducts periodic and targeted training and guidance for after-sales service personnel. As the saying goes, "no one is perfect, no gold is red", to help after-sales service personnel improve service skills and correct service attitude. Carry out relevant technical training for after-sales service personnel, so that after-sales service practitioners have professional product knowledge.