API 650 flexible liquid storage tanks check valve
The hardness of the welds contacting these environments, including the heat-affected zones, shall be considered. The weld metal and adjacent heat-affected zone often contain a zone of hardness that is well in excess of a value of 22 on the Rockwell C scale and could be expected to be more susceptible to cracking than would unwelded metal. Any hardness criteria shall be a matter of agreement between the Purchaser and the API 650 flexible liquid storage tanks manufacturer and shall be based on an evaluation of the expected hydrogen sulfide concentration in the product, the possibility of moisture being present on the inside metal surface, and the strength and hardness characteristics of base metal and weld metal.
API 650 petroleum storage tank pipeline stress and product pressure, tank pressure, uniform or non-uniform temperature difference between the tank wall and the tank bottom, which cause the radial displacement and longitudinal rotation of the API 650 flexible liquid storage tanks tank wall at the opening to affect the oil tank wall The impact is obvious. Therefore, the design must ensure that the load applied by the external pipeline on the opening of the tank wall is within the safety limit. If the stress of the API 650 flexible liquid storage tanks connecting piping is not handled properly, the wall of the API 650 petroleum storage tank may deform or even rupture, causing a major accident.
In 2016, we brought our customer to visit our NM400 hot rolled plate; producing line and our shanghai warehouse for 30,000 tons plate and structure. As a result, Our client purchased 500 tons NM400 as first order, which is shipped by 3 times. In future. Our company will always guarantee that all the delivery condition for Hardox plate API 650 flexible liquid storage tanks provided will be with quenching and tempering, which is the best delivery type according GB/T 24186 standard.
}In order to prevent the deformation of the bottom of metal vertical API 650 flexible liquid storage tanks during welding, comprehensive control measures such as strict control of assembly geometry size, reasonable welding procedure, process control of welding deformation and rigid fixation are adopted during assembly welding. The specific methods are as follows:1. Strictly control welding groove forming of API 650 flexible liquid storage tanks.2. Strictly control the size of tank welding seam assembly.3. Define the welding sequence of tank bottom plate.4. Reasonable distribution of welders.
We should focus on the main problems to be solved and pay attention to efficiency. After receiving the user's quality objection report data, the possible causes, responsible units, compensation amount, etc. of the problem shall be judged based on experience. To have a clear service plan, to be clear about what your main problem is, what technical support is needed, these should be prepared.