API 650 fixed roof tanks lining

Under the same sealing effect, the internal API 650 Fixed roof tanks floating roof API 650 tank can further reduce the evaporation loss compared with the external floating roof API 650 tank. This is due to the shielding of the fixed roof and the gas phase layer between the fixed roof and the inner floating plate, which has more significant heat insulation effect than the double disc floating roof of the API 650 fixed roof tanks external floating roof tank.

Since its establishment, the company has been deeply supported and loved by customers with its unique business philosophy and business model. The company has always adhered to the tenet of "credibility first, integrity-based, quality first" and sincerely serves new and old customers. At the same time, it keeps pace with the times based on market orientation, continuously expands offline channels, and gradually establishes a complete online E-commerce business management platform. We will always promote our after-sales service to make client satisfied with our goods.

Temperature Range: The provisions in this appendix are considered suitable for API 650 fixed roof tanks design metal temperatures from + 40°F to –60°F, inclusive. In general, refrigerated tank primary components include those components whose failure would result in leakage of the liquid being stored, those exposed to the refrigerated temperature, and those subject to thermal shock. Further definitions of such components are provided in API Standard 620 tank R.1.4.2 and R.1.4.3.

How to effectively increase the service life of API 650 fixed roof tanks oil tanks? It is necessary to check and inspect the oil tank regularly in the process of use, and do a good job in the maintenance and cleaning of the oil tank. The oil tank should be inspected every 6 years. With the increase of service life, the inspection interval should be shortened. Daily maintenance and cleaning of the API 650 fixed roof tanks can prolong the service life of the oil tank. The maintenance of the API 650 fixed roof tanks mainly includes the anti-corrosion inspection of the oil tank, the maintenance of the accessories, and the cleaning of the sediment in the tank.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!