API 650 cylindrical liquid-storage tank sliding resistance

Shell Stiffening Rings for Tanks That Contain Liquid
Internal or external shell stiffening rings may be required to maintain roundness when the tank is subjected to wind, vacuum, or other specified loads. When API 650 cylindrical liquid-storage tank stiffening rings are required, the stiffener-to-shell weld details shall be in accordance with Figure Q-1 and Q.3.5.2 through Q.3.5.5.
Three-plate laps or butt-weld junctions in tank bottoms shall be not closer than 12 in. from each other or from the butt-welds of the annular plates.
Bottom plates, other than annular bottom plates for a 9% or 5% nickel steel or stainless steel tank that contains liquid, may have a minimum thickness of 3/16 in. exclusive of any specified corrosion allowance.

The Standard has gained international recognition and is the standard of choice of most builders of large liquid above ground API 650 cylindrical liquid-storage tank storage tanks. One reason for this is that the API 650 Standard was created and is revised by API committees comprised of the world s best tank structural engineers who also rely on the experience of tank owners and tank construction companies.

In 2015, we offered 230 tons 309S and 310S stainless steel API 650 cylindrical liquid-storage tank plate to Vietnam fabrication company. The products are used in fabricating machine for this company. Then the customer sell the machine to south America and European market. This Vietnam company purchase more than 100 ton stainless steel from us every month.

}

The manufacturing requirements of bottom plate of vertical metal tank, API 650 cylindrical liquid-storage tank are as follows: 1. In order to compensate welding shrinkage, the layout diameter of tank bottom is 5-2mm than the design diameter; 2. The butt joint of edge plate of tank bottom shall be machined automatically or semi-automatically; 3. The distance between any two adjacent welding joints on the tank bottom plate and the distance between the butt joint of edge plate and the longitudinal weld of bottom ring wall plate shall not be greater than 200 mm.

We should focus on the main problems to be solved and pay attention to efficiency. After receiving the user's quality objection report data, the possible causes, responsible units, compensation amount, etc. of the problem shall be judged based on experience. To have a clear service plan, to be clear about what your main problem is, what technical support is needed, these should be prepared.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!