aluminum sheet 5456 API 650 liquid storage tanks
In cylindrical tank walls, the longitudinal weld joints in adjacent shell courses, including compression ring welds, shall be offset from each other a minimum distance of 12 in. The butt-weld around the periphery of a thickened insert plate, or the fillet weld around the periphery of a reinforcing plate, shall be at least the greater of 10 times the shell thickness or 12 in. from any butt-welded seam or the bottom-to-shell or roof-to-shell joint. As an alternative, the insert plate (or the API 650 liquid storage tanks reinforcing plate in an assembly that does not require stress relief) may extend to and intersect a flat-bottom-to-shell corner joint at approximately 90 degrees.
API 650 is the standard for welded tanks for oil storage. It specifies the design, manufacturing, welding, inspection and installation requirements of oil tanks. API 650 API 650 liquid storage tanks is widely used in storage tanks with internal pressure less than or equal to 2.5 PSI, used to store products such as crude oil, gasoline, chemicals, and produced water. BBN has extensive experience in API 650 liquid storage tanks API 650 tanks with diameters between 8'-300', suitable for refineries, terminals, pipeline facilities and other customers.
BBN steel had provided Grind plates for more than 15 years for widely applied in equipment, Engineer machinery etc. In 2018, one of our India customer visit our API 650 liquid storage tanks office and work shop to discuss Q235B Grind plate technical request, they have strict surface and thickness tolerance, and they also request UT and MT for testing. As a result, they purchase API 650 liquid storage tanks 179 tons as trial order for first cooperation. And have good comment on our quality. Till now, we keep exporting around 100 tons per month as regularly.
}The cone slope of the completed API 650 liquid storage tanks foundation is 15/1000 for the general foundation and less than 35/1000 for the soft foundation. After the foundation settlement of the storage tank is basically stable, the surface slope must be greater than eight thousandths. The edge of the tank bottom should be more than 0.3 meters higher than the surrounding ground. Above the ground, the tank bottom leakage detection tube should be drawn from the foundation sand cushion and cross the foundation ring wall or the slope protection surface. The circumferential distance should be less than 20 meters, and each API 650 liquid storage tanks should have at least 4 detection tubes.
Before delivering our hot rolled plate product we apply various tests to check the quality of carbon steel API 650 liquid storage tanks plates such as- mechanical test, chemical test, hardness test, toughness test, eddy current test, impact test, micro test, flaring test, flattening test, etc. We are provided best packing for structural steel plates to avoid rust. Our after-sales service team will contact you if you have any question.