Uplift on FoundationFor API Standard 620 tanks with an internal design pressure less than 1 lbf/in.2 gauge, the uplift shall be taken as the smaller of the maximum uplift values computed under the following conditions:a)The internal design pressure times 1.5 plus the design wind load on the shell and roof.b)The internal design pressure plus 0.25 lbf/in.2 gauge plus the design wind load on the shell and roof.
This specification, in conjunction with API 650 Standard, prescribes minimum standards for the API Std 650 liquid storage tanks design, supply, fabrication, erection, and testing of field erected welded steel storage tanks complete with accessories as specified herein and as shown on attached Datasheets and/or Drawings.
Crack treatment of API Std 650 liquid storage tanks weld area: find out the crack tip with ray or ultrasonic flaw detection, drill cut-off holes at both ends of the crack with the cut-off method, the hole depth is slightly greater than the crack depth, or groove (crack stop groove) is made by angle grinder at both ends of the crack, shovel and grind the whole crack, and grind it into a suitable groove; use radiographic inspection and dye detection to verify that the crack has been completely excavated, and finally repair welding.