The horizontal projection of the roof plate within the compression-ring region is 4.9 x 0.866 = 4.25 in., which fulfills the requirement of API 620 tank standard 5.12.5.1. The required area and horizontal projection can be provided by any of the standard angles listed in Table F-3.
Any of these angles may be used in accordance with the details of Figure 5-6, detail a or b, but if details c, h, or i in Figure 5-6 were intended, the net area of the angle must be calculated by deducting the area expected to be lost by corrosion from that part of the angle surface that is exposed to the interior of the tank.API 650 Tanks in which liquid fluids are stored and designed to withstand atmospheric pressure operation, less than 18 kPa, or internal pressures not exceeding the weight of the API Std 650 carbon and low-alloy steel tanks roof, with temperatures no higher than 93, 3 C are included in the scope of this design code.In April 2018, our Philiphine customer purchased 1008 Tons API5L Gr.B ERW&Q345B SMLS pipe for offshore oil field resources drilling project. This is a regular demand almost two month, and we has been cooperated more than three times, totally around 2100 tons steel pipe since 2015 year.Safety comparison between mechanical cleaning and manual cleaning of vertical storage tank, API Std 650 carbon and low-alloy steel tanks. Closed cleaning is adopted for mechanical cleaning. During the cleaning process, operators are not required to enter the tank. The inert gas space formed in the storage tank can prevent the occurrence of fire, explosion and other accidents. When the API Std 650 carbon and low-alloy steel tanks is manually cleaned, the operators should directly enter the tank for cleaning, threatening the health of employees, and there is no inert gas space in the tank, which is prone to fire and explosion accidents.The 365 day service system is implemented, and the business, loading and delivery are handled as usual in holidays and festivals. Actively help users solve difficulties. When users encounter difficulties in handling business, they should actively coordinate with the external solution; if they need to solve the problems internally, they should solve them in a timely manner without prevarication and wrangling. In line with the API Std 650 carbon and low-alloy steel tanks principle of "fairness, justice and timeliness", coordinate with relevant departments and deal with all kinds of objections in a timely manner.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!