A333 grade 6 pipe API 650 self anchored flatbottom tanks

In this project, an area of tank wall is constructed of ASTM A285, Grade C, steel plate that is 5/8-in. thick and has spot-radiographed, double-welded butt joints. The wall is subject to tension in a meridional direction and to compression in a latitudinal direction. The values of R1 and R2 at the point under consideration are 75 in. and 300 in. respectively. A corrosion allowance of 1/16 in. is required. The computed (meridional) tensile stress, stc, in the net thickness after deduction of the corrosion allowance is 6000 lbf/in.2.
The problem in this example is to find the maximum allowable (latitudinal) compressive stress value for the given conditions, in conformance with the provisions of API 620 tank standard 5.5.4.5.

Before the start of erection, inspect each API 650 tank foundation to ensure that it is level and acceptable to receive Work. Remove temporary erection attachments welded to the interior or exterior of the API 650 self anchored flatbottom tanks shell or to the bottom by arc gouging, and grind weld area smooth.

In 2015 , We get the tender from Myanmar Government, the total quantity is 1200 ton ABS-AH36 steel plate, we supply the steel plate with painting ( which standard is according to ISO SA2.5) with gray Color 20 Micron. After Get Customer Contract, Steel Plate Are Produced within 25 days .Then, Goods transported to Tianjin Port And Shipping On Time To Statisfy With Project Expected After Finished Producing. The Steel Quality API 650 self anchored flatbottom tanks we offered receive good Praise from our Customers .

}

Generally, external environment corrosion should be considered before design and construction of API 650 self anchored flatbottom tanks and so on storage tanks. The corrosion on the outer surface of storage tank is often worse than that on the inner surface. Especially in the chemical industry area, there are often acid fog, alkali or salt dust in the atmosphere. These impurities form an active corrosive medium with dew or steam and oxygen in the atmosphere. The corrosion of the external environment of the storage tank shortens the maintenance period of the storage tank, even causes the storage tank to be scrapped in advance, which affects the normal operation of the storage and transportation.

We should focus on the main problems to be solved and pay attention to efficiency. After receiving the user's quality objection report data, the possible causes, responsible units, compensation amount, etc. of the problem shall be judged based on experience. To have a clear service plan, to be clear about what your main problem is, what technical support is needed, these should be prepared.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!