A131 Gr B plates API Std 650 ground-supported liquid storage tanks
The cleanliness of the API Std 650 ground-supported liquid storage tanks has a great influence on the safety of the tank and the quality of the oil stored. Keeping the API Std 650 ground-supported liquid storage tanks clean can slow down the corrosion of the tank wall and reduce the pollution to the oil. If the inside of the API Std 650 ground-supported liquid storage tanks is not cleaned all the year round, a lot of rust and metal impurities will be produced in the tank. These impurities will cause the oil to slowly oxidize and deteriorate. The impurities mixed into the oil will also block the filter and oil circuit, causing oil supply failure.
Upon completion of construction, provide Purchaser with copies of Field Erected API Std 650 ground-supported liquid storage tanks Storage Tank Datasheets in accordance with Appendix L of API 650, which reflects the as-built conditions, certifying that the tank conforms with the requirements of this specification.
The company's logistics department has the ability to monitor the whole process of logistics. We monitor the goods in transit through advanced information technology and communication technology, timely discover and handle problems in the transportation process, and ensure the steel materials are delivered to the destination in a timely and safe manner. The professional logistics team provides powerful support for good comments of customers and good reputation of the company.
Preheating should be performed by heating and maintaining this heat in appreciable lengths of the joint to be welded, preferably using a strip burner with a mild flame rather than a harsh flame such as that from a cutting torch. Electrical strip heaters are available and have been found to be satisfactory. The preheat of 300°F should be checked with a temperature-sensitive crayon, or similarly accurate means, so that the steel 4 in. (or four times the API Std 650 ground-supported liquid storage tanks plate thickness, whichever is greater) on each side of the joint will be maintained at the minimum preheat temperature. Ring burners or heaters are recommended for nozzle and manway welds. At no time during the welding should the base metal fall below a temperature of 300°F.