The calculated thickness of the above-mentioned wall panels required by the hydrostatic pressure is also It API Std 650 flat-bottom oil storage tanks should be increased by the same ratio, unless special analysis is performed to determine the seismic overturning moment and the corresponding stress at the bottom of the wall of each layer of API 650 tank.

To scientifically evaluate the remaining service life of the API Std 650 flat-bottom oil storage tanks, it is necessary to know the thickness change and development trend of the storage tank sheet after long-term use, combined with the metal characteristics of the storage tank, the influence of various external conditions and the continuous change of the oil pressure in the API Std 650 flat-bottom oil storage tanks, etc. factors to judge. Because the metal characteristics, corrosion defects, load and other numerical parameters of the API Std 650 flat-bottom oil storage tanks are randomly changed, the value of the remaining service life of the storage tank will also be dynamic.

Investigation of Subgrade
On actual steel storage tank sites to be used, test borings or test pits, or both, may be made at the direction of a competent engineer who will specify the number and location. They need not be equally spaced but should be laid out to uncover possible weak spots.
In general, test loadings of subgrade at the bottom of test pits need be resorted to only when such heavy loading as may be imposed by footings for major column supports for spheres or similarly elevated API 620 low-pressure tanks is specified. Results may be deceptive if average load-bearing capacity over a considerable area is wanted. All field data shall be recorded with maps, and copies shall be supplied to all engineers concerned with design, erection, and later operation.

BBN company team and culture: tt the end of 2019, in order to thank employees for their hard work and enrich their sparetime lives, the company organized a pleasant trip to Phuket Island, Thailand. This tour lasted 6 days and 5 nights, and returned by plane on the evening of December 27. We took off in Zhengzhou at about 5o'clock in the afternoon on the 22th December. Let's seize the day and live it to the full, and greet the arrival of the year 2020 together.

The company adheres to the needs of customers, adheres to win-win integrity, and relies on scientific and technological innovation to continue to improve the level of logistics equipment technology and information technology, and enhance the logistics technology research and development and innovation capabilities. Based on market demand and innovation as the driving force for development, the company actively expands the field of logistics services, accelerates the extension of the logistics industry chain, and scientifically advances the diversification of the logistics industry.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!