5254 aluminum pipe API Std 650 floating-roof tanks

Large Steel storage tank Anchorage
In addition to the loads in API 620 oil storage tank Q.4, Q.5.1, and Q.5.2, the anchorage for the tank that contains liquid, whether it be a single-wall tank or the inner tank of a double-wall tank, shall be designed to meet the requirements of Q.3.6.2 through Q.3.6.5. The anchorage shall accommodate movement of the tank wall and bottom caused by thermal changes. For anchored flat-bottom tanks, the anchorage shall be designed as described in Q.3.6.4.1 through Q.3.6.4.3.Floating roofs shall comply with API standard 650, Appendix C (Attachment 01) or with the API Std 650 floating-roof tanks requirements as layed (laid )down in the national Chinese specifications SH3046-92 and GBJ128-90.With the fast development in Myanmar, Myanmar navy build frigate every year. We Cooperate with Myanmar Navy from 2015. They purchased 412 ton LR AH36 steel plate from us as trial order in 2015. After receiving the API Std 650 floating-roof tanks goods, they speak highly of the quality and our service. After that they purchase the shipbuilding steel plate from us regularly. In May,2018, the Myanmar navy’s local representative visit our office and production line, and sign another contract 2025 ton steel order in our office.Welding inspection of bottom plate of API Std 650 floating-roof tanks, vertical oil tank: During the fabrication and installation of API Std 650 floating-roof tanks, the bottom edge plate is welded first. According to the requirements of the technical standard, penetrant inspection is required for the weld of edge plate at the bottom of API Std 650 floating-roof tanks, that is, penetrant testing is required for each weld bead priming, filling and capping. In the process of testing, if any defect is found, it shall be repaired immediately. After the repair, the surface coloring penetrant test shall be conducted again until the test result is qualified.The 365 day service system is implemented, and the business, loading and delivery are handled as usual in holidays and festivals. Actively help users solve difficulties. When users encounter difficulties in handling business, they should actively coordinate with the external solution; if they need to solve the problems internally, they should solve them in a timely manner without prevarication and wrangling. In line with the API Std 650 floating-roof tanks principle of "fairness, justice and timeliness", coordinate with relevant departments and deal with all kinds of objections in a timely manner.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!