12m diameter API standard 650 ground supported tanks
Uplift on FoundationFor API Standard 620 tanks with an internal design pressure less than 1 lbf/in.2 gauge, the uplift shall be taken as the smaller of the maximum uplift values computed under the following conditions:a)The internal design pressure times 1.5 plus the design wind load on the shell and roof.b)The internal design pressure plus 0.25 lbf/in.2 gauge plus the design wind load on the shell and roof.
API 650 internal floating roof oil tank is a volatile liquid storage tank with a combination of a dome tank and an internal floating roof structure, which is a floating roof assembled under the dome of the API standard 650 ground supported tanks storage tank. The combination of the vault roof outside the API 650 storage tank and the floating roof inside the tank has been widely used in gasoline, aviation kerosene and more volatile chemical liquids.
Usually, the wind load in the API standard 650 ground supported tanks construction area should be considered before the tank design and construction. The wind load in the API standard 650 ground supported tanks construction area has an impact on the stability and economy of the API standard 650 ground supported tanks. In the area with large wind load, it is safe to design the tank as "squat". When calculating the wind force, the influence of the thickness of the insulation layer of the API standard 650 ground supported tanks, the shape of the ladder, the platform, the pipeline and the top cover must be considered.