1060 aluminum shapes API standard 650 petroleum storage tanks

API 650 is used to store products such as crude oil, gasoline, chemicals, and produced water. BBN has extensive experience in API standard 650 petroleum storage tanks API 650 tanks with diameters between 8'-300', which are suitable for refineries, terminals, pipeline facilities and other projects.

After years of operation and accumulation, the company has formed an operation network covering major economic cities across the country, with a group of high-quality professional logistics technicians and management personnel, strong strength and stable logistics channels. The company's business operations include the loading and unloading of steel raw materials and finished materials, API standard 650 petroleum storage tanks warehousing, and freight transportation. Our logistics service business has passenger transportation, automobile and construction machinery inspection, logistics information management and operations.

The pressed-steel, round manhole with a 20-in. inside diameter shown in Figure F-8 is located in API 620 crude oil tank solid plate in spherical portion of a torispherical roof on a cylindrical storage tank 72 ft in diameter. The internal pressure, Pg, on the underside of the roof is 15 lbf/in.2 gauge. The thickness, t, of the roof plate required by 5.10.3 for the spherical portion of the roof is 1/2 in., which is exactly the thickness provided. No corrosion allowance is required. The materials in the oil tank roof plates and manhole frame conform to ASTM A283 Grade C steel; the main joints in the roof are double-welded butt joints, spot radiographed in accordance with 7.16 and 7.17.

Welders participating in the construction of API standard 650 petroleum storage tanks must pass the examination and perform welding within the validity period of the qualified items. Special operators such as on-site maintenance electricians, cranes, and shelf workers must hold job certificates. All oil pipelines need to use arc welding for bottoming and electric welding to ensure the welding quality. Oil tanks and process pipelines must be tested for non-destructive flaws in accordance with the flaw detection ratios and methods required by the design and acceptance specifications. The flaw detectors must be certified.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!