The maximum design liquid level of API 650 uplifting tanks

Treatment of API 650 uplifting tanks welding defects:
1. Lack of fusion: once found, it should be shoveled and grinded off before re welding.
2. Incomplete penetration: over standard defects shall be removed and re welded. When welding on both sides, the shallow side of the groove can be grinded and shoveled to expose the welding root on one side, and then the welding is repaired.
3. Slag inclusion: over standard defects shall be removed and re welded.
4. Crater: weld to full after grinding.
5. Air hole: if the internal air hole exceeds the standard, it shall be welded again after being removed by grinding shovel, and the surface air hole shall be removed by grinding wheel and then repaired.For all API 620 crude oil tank other materials, the impact test temperature shall be at least 30°F colder than the design metal temperature. Alternately, materials impact tested at the design metal temperature or lower with Charpy impact test energy value of 25 ft-lb (average), 20 ft-lb (minimum) are acceptable for design metal temperatures above –40°F. API 650 uplifting tanks materials with an energy value of 30 ft-lb (average), 25 ft-lb (minimum) are acceptable for design metal temperatures of –40°F or lower.Under the same sealing effect, the internal API 650 uplifting tanks floating roof API 650 tank can further reduce the evaporation loss compared with the external floating roof API 650 tank. This is due to the shielding of the fixed roof and the gas phase layer between the fixed roof and the inner floating plate, which has more significant heat insulation effect than the double disc floating roof of the API 650 uplifting tanks external floating roof tank.The company has always adhered to the corporate purpose of “improving benefits, creating wealth, benefiting employees, and giving back to the society”. We adhere to the corporate spirit of ""innovation, efficiency, integrity, and win-win"", attract first-class talents, strive for first-class indicators, create first-class benefits, build first-class enterprises, pursue excellence, innovative development, and efficiently serve the coordinated development of the Beijing-Tianjin-Hebei and the ""Belt and Road"" Economic development strategy.BEBON is willing to cooperate with friends from all sides for a win-win development!The alloy steel plate is among our business scope, and it is one of our main product. If you have any demands or questions about alloy steel plate, such as 34CrMo4 API 650 uplifting tanks material properties, 42CrMo4 AISI equivalent, 12Cr1MoV equivalent ASTM, 40Cr material specification, 42CrMo hardness, 50CrMo4 chemical composition and so on, please free free to communicate with us. We have professional technical team and sales team, who will give you API 650 uplifting tanks professional answers and quotation about alloy steel plate in time.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!