Open top API standard 650 duplex stainless steel tanks

The establishment of a correct method for evaluating the life of API standard 650 duplex stainless steel tanks requires the preparation of criteria related to the strength and cracks of API standard 650 duplex stainless steel tanks, mechanical damage mechanisms, corrosion mechanisms, and mathematical models of fatigue crack growth, etc., which are compiled into computer programs. In the process of programming the program, it is required to select the operating parameters, plates, reinforcement accessories, metal properties, corrosion levels, mechanical damage defects and other data of the oil storage tank under various conditions.

A cylindrical nozzle with a 12-in. inside diameter is located in solid plate in the sidewall of a cylindrical storage tank 60 ft in diameter so that its axis lies in a horizontal plane and forms an angle of 55° with a perpendicular to the sidewall at the point of intersection, as shown in Figure F-7. The thickness of the API standard 650 duplex stainless steel tanks sidewall plate, tw, in this area is 5/8 in., and no corrosion allowance is required. The total internal pressure, Pl + Pg, at the center of the opening is 26.1 lbf/in.2 gauge.

The API Std 650 standard published by the American Petroleum Institute (API) is designed to provide the petroleum industry with welded steel tanks for use in the API standard 650 duplex stainless steel tanks storage of petroleum products and other liquid products commonly handled and stored by the various branches of the petroleum industry.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!