Maximum design temperature of API 650 welded steel oil storage tanks

Deformation of the welding seam of the API 650 welded steel oil storage tanks is a common quality problem during the actual use of the API 650 welded steel oil storage tanks, which easily causes the tank body to leak and affects the safety of the oil storage tank. The welding seam deformation of the API 650 welded steel oil storage tanks is mainly caused by the lack of reserved welding seam gap and irregular operation. The oil storage tank has not reserved the corresponding weld gap, resulting in deeper root removal during the front welding activity. The heat output of the weld will increase under the influence of a long time, and the deformation of the weld will gradually become serious.

Low-pressure Storage Tanks Fireproofing
Although general fire prevention and fire protection measures are expected to be fully covered by other safety codes, tanks API 650 welded steel oil storage tanks constructed according to these rules, which may be subject to fire exposure resulting from any cause, shall have their supports suitably fireproofed.
Special consideration shall be given to provisions for ample drainage facilities for accidental spills or leakage of flammable contents from such tanks or adjacent piping and other equipment if the contents may become ignited.
Subject to special considerations in isolated locations, tanks in which flammable liquid products are stored at temperatures well above their average boiling point shall be suitably fireproofed or otherwise protected.

API 650 internal floating roof API 650 welded steel oil storage tanks tank can be used to store gasoline, jet fuel and other volatile oil products, as well as aldehydes, alcohols (methanol, ethanol), ketones (acetone), benzene (benzene, toluene, xylene, styrene) and other liquid chemicals.

Enterprise Motto:Integrity, harmony, dedication, innovation and developmentAbility is the cornerstone of success; action is the ladder of successGrow with the enterprise; progress with the enterpriseGive a platform to those who actually do things and a stage to those who successfully do thingsDare to be the first, to pursue excellence.

S355J2 hot rolled steel plate executive standard: EN10025-2S355J2 hot rolled steel plate delivery status: control binding, normalizing rolling, normalizingThe European standard S355J2 hot rolled steel plate is available from API 650 welded steel oil storage tanks stock and can be cut and processed according to the requirements of customers; the futures can be produced according to your requirements, and our S355J2 hot rolled steel plate price is preferential and the delivery time is fast, welcome to contact and purchase.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!