Dome roofs API 650 closed top welded storage tanks
Allowable compressive stresses shall be in accordance with 5.5.4 except that for aluminum alloy plate the allowable compressive stresses shall be reduced by the ratio of the modulus of compressive elasticity to 29,000 for values of (t – c)/R less than 0.0175 and by the ratio of the minimum yield strength for the aluminum alloy in question to 30,000 for values of (t – c)/R equal to or greater than 0.0175 (see 5.5.2 for definitions). In all other equations in this standard API 650 closed top welded storage tanks where yield strength or modulus of elasticity is used, such as Equations 27 and 28, similar corrections shall be made for aluminum alloys.
API 650 petroleum storage tank pipeline stress and product pressure, tank pressure, uniform or non-uniform temperature difference between the tank wall and the tank bottom, which cause the radial displacement and longitudinal rotation of the API 650 closed top welded storage tanks tank wall at the opening to affect the oil tank wall The impact is obvious. Therefore, the design must ensure that the load applied by the external pipeline on the opening of the tank wall is within the safety limit. If the stress of the API 650 closed top welded storage tanks connecting piping is not handled properly, the wall of the API 650 petroleum storage tank may deform or even rupture, causing a major accident.
The Indonesia INKA is the only train carriage maker for railway industry in Indonesia. We cooperated with them since 2012 and supply them SPA-H steel. The SPA-H steel is used by them to fabricate train carriage. We have huge stocks for SPA-H steel and can arrange delivery for them in short time after receiving order. Meanwhile, our product API 650 closed top welded storage tanks quality has passed their test for so many times use. Therefore, they trust us and give us repeat orders regularly. And we also do our best to support them and have never let them down though past cooperations.
}The water dissolved in the oil will be separated out from the oil stored in the API 650 closed top welded storage tanks for a long time, and the acidic water layer will appear at the bottom of the API 650 closed top welded storage tanks for a long time, which will accelerate the corrosion of the API 650 closed top welded storage tanks and cause the wall thinning and even leakage. With the increase of service life, the API 650 closed top welded storage tanks must be inspected and cleaned regularly to check the hidden danger.
After-sales service team is a key department to test the steel quality. Product quality is always the foundation of our survival and development. The company's full inspection from raw materials to finished products; and implements standardized, scientific, and strict internal quality control and management systems in accordance with the process flow during the production process; products can only leave the factory if qualified, and follow-up problem solving systems are implemented in after-sales services to guarantee the customers’ interest.