ASTM A671 pipe API 650 ground supported flat-bottom tanks
Structural shapes of 9% and 5% nickel steel may be furnished to the chemical and physical requirements of ASTM A353, A553, or A645. Physical tests shall be in accordance with the requirements of ASTM A6.API 650 ground supported flat-bottom tanks used Piping, Tubing, and ForgingsMaterial used for piping, tubing, and forgings shall be compatible in welding strength, and thermal expansion coefficient with the tank shell material. In addition to the specific requirements of this appendix, all piping within the limitations of 1.3.2 shall fulfill the minimum requirements of ASME B31.3.
API 650 internal floating roof tanks are generally called internal floating roof tanks, floating roof tanks, internal floating disk storage tanks, internal floating disk tanks, etc., specifically referring to API 650 storage tanks and oil tanks with aluminum, stainless steel, etc. The API 650 ground supported flat-bottom tanks inner floating roof of series material is an environmentally friendly and economical storage tank that prevents liquid from volatilizing.
API 650 ground supported flat-bottom tanks weld tightness test: remove dirt from the API 650 ground supported flat-bottom tanks weld, apply white powder emulsion, spray kerosene on the other side of the weld after drying. Because of the strong penetration of kerosene, if kerosene is sprayed after 12 hours (under low temperature conditions, the time can be extended), if the surface of the welded seam coated with white emulsion has no spots, the welded seam meets the requirements.